  "date": "2026-10-22",
  "scope": "reference_example",
  "energyplus_version": "26.1.0-6f2e40d102",
  "method_id": "power_hourly_design_conditions_v1",
  "reference_period": {
    "start_year": 2006,
    "end_year": 2025
  },
  "site": {
    "label": "Faridpur NASA POWER grid point (not station observations)",
    "latitude": 23.6,
    "longitude": 89.85,
    "elevation_m": 9.0,
    "utc_offset_hours": 6.0
  },
  "hour_count": 175320,
  "case_count": 13,
  "source_manifest_sha256": "655002937ea91e2975df039d949e2bd1e98beb189f5f44603459ce785c91e310",
  "ddy_sha256": "a26dcfbd8e880d23b160c708476ffc2e0ca9e6190c9ec0d8e2acb12f3df44153",
  "design_conditions_sha256": "bb97c2033e7ad9c041de036494cb868d744b3b73e294d1f424f296675083aa06",
  "native_verification": "passed",
  "scientific_validation": "not_assessed",
  "hosting_acceptance": "not_performed",
  "native": {
    "environment_count": 13,
    "zone_sizing_periods": 13,
    "system_sizing_periods": 13,
    "timesteps_per_day": 144,
    "warning_count": 3,
    "severe_count": 0,
    "warning_messages": [
      "   ** Warning ** SizeWaterCoil: Potential issue with equipment sizing for Coil:Heating:Water OA HEATING COIL 1",
      "   ** Warning ** The design coil load is zero for Coil:Heating:Water OA HEATING COIL 1",
      "   ** Warning ** InitController: Controller:WaterCoil=\"OA HC CONTROLLER 1\", Maximum Actuated Flow is zero."
    ],
    "zone_sizing_rows": 10,
    "system_sizing_rows": 2,
    "autosized_component_rows": 45,
    "maximum_abs_differences": {
      "dry_bulb_c": {
        "value": 4.982609880244127e-10,
        "unit": "C"
      },
      "relative_humidity_percent": {
        "value": 4.970601708009781e-10,
        "unit": "%"
      },
      "humidity_ratio_kg_kg": {
        "value": 1.3543457778875112e-09,
        "unit": "kgWater/kgDryAir"
      },
      "wet_bulb_c": {
        "value": 1.928987979127328e-05,
        "unit": "C"
      }
    },
    "native_receipt_sha256": "28e87a906c5420386a360f9432a6470580c1d1079704f426fb92f77d38b37030",
    "native_idf_sha256": "7d34e0c2e881975b66441912f8817dff65bdcdd280d24cc10285d303bc28661a",
    "verification_program_sha256_at_run": "7b91815f1cfecb57b6e64ee5918783ebc30abe5d65ebf3c143cd800962434f29",
    "native_returncode": 0,
    "native_runtime_seconds": 2.8318310999893583,
    "posthoc_receipt_sha256": "085658c46decec0216b739a7f25d3d0eb7f51794db18b29481dd24b4341bec65",
    "posthoc_verifier_sha256": "197266af874a517cf6111dda3f1314df732da41ab22a811b2eb929ab05b55f54",
    "posthoc_date_utc": "2026-10-22T18:19:47.026614+00:00"
  },
  "limitations": [
    "Reference example only; a newly generated user DDY has not been run in EnergyPlus.",
    "Three warnings concern zero outdoor-air heating-coil sizing/flow in the bundled example; no severe errors.",
    "5ZoneAirCooled is a technical consumer fixture, not a validated building, floor/ground or energy model.",
    "Native derived wet-bulb diagnostics can differ from the bounded upstream-equation root; compare imposed DB/RH and conserved W separately.",
    "NASA climate accuracy and actual Beget deployment are not assessed by this example."
  ]
}