Stack effect analysis for tall buildings

In cold weather, differences in indoor and outdoor air density create pressure differences along a building’s height. We analyse stack effect to coordinate entrances, vertical connections and ventilation.

Why can a shaft affect a ground-floor door?

Outdoors, the lobby, floors and vertical shafts form a connected airflow system. Air movement depends on temperature, height, airtightness and open connections. It can affect door opening forces, cold-air infiltration and air distribution. We assess the whole system and use CFD where a local area requires more detailed analysis.

What we assess

  • Vertical pressure distributions and neutral pressure levels under selected temperature conditions.
  • Airflows between outdoors, entrances, floors and shafts, accounting for leakage and air connections.
  • Comparison of vestibules, shaft and air-zone separation, airtightness measures and ventilation operating modes.

Inputs for the calculation

Building height and floor count, plans and sections, entrance and shaft layouts, door and envelope information. The model also needs temperature conditions, leakage data and ventilation flow rates. We agree the operating conditions to assess.

What your design team receives

Pressure profiles, airflow paths and values across selected doors and zone boundaries. We compare the original scheme with proposed measures, identify the most influential air connections and provide findings for architects and building services engineers.

Illustrative study

A tower entrance and lift lobby

Compare a direct air connection between the entrance and lift lobby with a separated-zone arrangement. Under identical outdoor conditions, assess door pressure differences and entrance airflow. Then examine the effect of changing airtightness.

The decision this study supports

Which air connections should change to manage entrance pressures?

View the model ↗

Questions about the study

Is stack effect only a ventilation issue?

No. It originates from height and temperature differences, while its effects depend on architecture, airtightness, entrances and shafts. The study therefore brings several design disciplines together.

Can you investigate an existing building?

Yes. Pressure and temperature measurements, ventilation operating data and the actual condition of doors are useful. They help compare the model with observed building behaviour and assess possible measures.